국내전문학술

김규용, 남정수, 구경모, 이태규, & 박연진. (2011). 방수시트 고정철물 고정공법의 간이 내풍압성 평가방법의 제안. 대한건축학회 논문집-구조계, 27(3), 107-114.
김규용, 남정수, 구경모, 이태규, & 박연진. (2011). 방수시트 고정철물 고정공법의 간이 내풍압성 평가방법의 제안. 대한건축학회 논문집-구조계, 27(3), 107-114.
작성자 관리자
조회수 46 등록일 2011.03.22
주저자 미야우치 히로유키
교신저자 042-821-7731
공동저자 남정수, 구경모, 이태규, 박연진
학술지명 대한건축학회

Abstract

An evaluation method for determining the wind resistance of mechanically anchored waterproofing membrane systems is roposed which uses a straightforward test method to assess wind resistance of the membrane. To obtain basic data for wind esistance design of a waterproofing membrane system, two testswere conducted: a pressure test on a flat roof of a building and wind resistance test using a ring type specimen. Tests on the membrane anchored to the flat roof showed that, as might be expected, the force on the fastener section increased as the wind pressure became higher. The test method which uses the ring type specimen had good correlation with results derived from the pressure test conducted on the flat roof membrane based on the behaviour of the waterproofing membrane. This test specimen when tested for wind resistance was fractured at 56 the strength achieved in the static test. Finally, a method for the design of fasteners based on a wind pressure induced fatigue model was proposed in order to apply the results in the construction of a flat roof mechanically anchored waterproofing membrane system.